IS 10431 : 1994 MEASUREMENT OF AIR FLOW OF COMPRESSORS AND EXHAUSTERS BY NOZZLES
UDC 62151: 621639 : 62164731 : 5336 | MED 22 |
Reaffirmed 2018
1. Scope
This standard prescribes a method of measurement of air flow and free air delivery of positive displacement compressors and exhausters, both reciprocating and rotary types.
1.1 This standard deals with measurement of air flow by using standard flow nozzle in order to obtain consistent and generally acceptable results, within a specified tolerance.
1.2 This standard-does not deal with the compressors, giving a pressure rise of less than 00 I MPa and greater than 6 MPa.
2. References
2.1 The following Indian Standards are-necessary adjuncts to this standard:
1821 : 1987 Dimensions for clearance holes for bolts and screws ( third revision)
3601 : 1984 Steel tubes for mechanical and general engineering purposes (first revision)
3624: 1987 Pressure and vacuum gauges ( second revision)
5456 : 1985 Code of practice for testing of positive displacement type air compressors and exhausters (first revision)
5727 : 1981 Glossary of terms relating to compressors and exhausters (first revision)