IS 11287 : 2023 Bridge Insulations Testers (Magneto Generator Type) - Specification
1 SCOPE
1.1 This standard covers the requirements of portable bridge insulation testers (hand operated) enclosing in the same case a generator having a rated voltage of 100 V or more testers (hand operated) enclosing in the same case as a generator having a rated voltage of 100 V or more.
1.2 The scope of this standard is confined to hand-operated bridge insulation resistance testers. Mains-operated and motor-driven bridge insulation resistance testers may have to comply with additional requirements which do not form part of this standard.
2 REFERENCES
The standards given below contain provisions, which through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of these standards.
IS No. | Title |
IS 460 (Part 1) : 2020 | Test sieves - Specification: Part 1 Wire cloth test sieves (fourth revision) |
IS 1248 (Part 9) : 2021/IEC 60051-9 : 2019 | Direct acting indicating analogue electrical measuring instruments and their accessories: Part 9 Recommended test methods (fourth revision) |
IS 9000 (Part 7/Sec 1) : 2018/IEC 60028-2-27 : 2008 | Basic environmental testing procedures for electronic and electrical items: Part 7 Impact test, Section 1 Shock (test Ea) (second revision) |
IS/IEC 60068-1 : 2013 | Environmental testing: Part 1 General and guidance |