IS 11480 : 2023 Domestic Grillers for use with Liquefied Petroleum Gases - Specification

ICS 27.060.10

MED 23

Revised Standard from Last Update.

1. SCOPE

1.1 This standard specifies construction, operation, safety requirements, and tests for domestic grillers with or without boiling burners for burning gases at a rate not exceeding 1 000 g/h, intended for use with liquefied petroleum gases at 2.942 KN/m2 (30 gf/cm2) gas inlet pressure.

1.2 Requirements for controls or accessories given in this standard relate to those fitted as part of, or supplied with, particular appliances; they do not necessarily provide a complete specification for controls intended for general use and tested separately.

1.3 For convenience, this standard has been divided into three sections as follows:

Section 1 Construction

Section 2 Performance

Section 3 General

2. REFERENCES

The standards listed below contain provisions which, through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards listed below. In case the standards are to be referred in this clause they are to be listed as follows:

1483 : 1988 Specification for white bread (third revision)

4246 : 2002 Domestic gas stoves for use with liquefied petroleum gases - Specification (fifth revision)

5116 : 2020 Domestic and commercial equipment for use with LPG - General requirements (fourth revision)

6480 : 1988 Glossary of terms relating to domestic and commercial gas-burning appliances (first revision)