IS 11484 : 2024 Phenol Sulphonic Acid for Electroplating - Specification
1 SCOPE
This standard prescribes the requirements and the methods of sampling and test for phenol sulphonic acid in the form of para isomer used for electroplating, especially in the manufacture of electrolytic tinplate, electrotinned wires and copper plating and electrotinning.
2 REFERENCES
The standards given below contain provisions which, through reference in this text, constitute provision of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent edition of these standards:
IS No. | Title |
IS 1070 : 2023 | Reagent grade water - Specification (fourth revision) |
IS 1260 (Part 1) : 1973 | Pictorial markings for handling and labelling of goods: Part 1 Dangerous goods |
IS 3025 | Methods of sampling and test (physical and chemical) for water and wastewater: |
(Part 2) : 2019/ISO 11885 : 2007 | Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (first revision) |
(Part 65) : 2022/ISO 17294-2 : 2016 | Application of inductively coupled plasma mass spectrometry (ICP-MS) - Determination of selected elements including uranium isotopes (first revision) |
IS 4905 : 2015/ISO 24153 : 2009 | Random sampling and randomization procedures (first revision) |
IS 13320 : 1992 | Determination of iron by atomic absorption spectrophotometry - Test method |