IS 11538 : 2024 Design and Installation of Farm Drainage Pumping Plants - Code of Practice
1 SCOPE
This standard covers the guidelines for design and installation of pumping plants for farm drainage purposes.
NOTE - This standard does not cover the pumping plant for deep well drainage.
2 REFERENCES
The standards listed in Annex A contain provisions, which through references in this text constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent edition of these standards.
IS No. | Title |
IS 2951 | Recommendation for estimation of flow of liquids in closed conduits: |
(Part 1) : 1965 | Head loss in straight pipes due to frictional resistance |
(Part 2) : 1965 | Head loss in valves and fittings |
IS 8034 : 2018 | Submersible pumpsets - Specification (third revision) |
IS 9694 (Part 2) : 2023 | Selection, installation, operation and maintenance of horizontal centrifugal pumps for agriculture application - Code of practice: Part 2 Installation (first revision) |
IS 10907 : 1984 | Code for design of farm drainage tile or pipe system |
IS 14536 : 2018 | Selection, installation, operation and maintenance of submersible pumpset - Code of practice (first revision) |
IS 17018 (Part 1) : 2022 | Solar photovoltaic water pumping systems: Part 1 Centrifugal pumps - specification (first revision) |