IS 12933 : Part 3 : 2003 Solar Flat Plate Collector - Specification - Part 3 : Measuring Instruments
ICS 27.160 | MED 4 |
|
Reaffirmed 2019 |
1 Scope
1.1 This standard (Part 3) specifies the measuring instrumentsfor solar flat plate collector for water heating.
1.2 This standard does not apply to the following:
a) Collector in whom heat transfer fluid may change phase, thatis, the collectors designed for normal fluid temperature above100°C with water as the heat transfer fluid;
b) Concentrating collectors, used in a system designed togenerate mechanical energy/electricity;
c) Collectors in which the thermal storage unit is an integralpart of the collector so that the collection and the storageprocesses cannot be separated;
d) Unglazed flat plate collector;
e) Installation or mounting of solar collectors; and
f) Tracking mechanism of the sun following collector system.
2 References
IS 2806 : 1992 Guide to electrical resistance thermometry
IS 3636 : 1966 Method of test for temperature coefficient of precisionresistor wires
IS 8336 : 1977 Thermoelectric pyranometer
IS 12934 : 1990 Solar energy - thermal applications - Vocabulary