IS 13021 : Part 1 : 1991 AC supplied electronic ballasts for tubular florescent lamps: Part 1 General and safety requirements

UDC 621.327.534.15.032.4 ETD 23
Reaffirmed 2016

1 Scope

1.1 This standard (part 1) specifies general and safetyrequirements for electronic ballasts for use on ac supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating fromthe supply frequency associated with tubular fluorescent lamps asspecified in IS 2418 : Part 2 : 1977 and other tubular fluorescentlamps for high frequency operation.

2 References

IS 2418 : Part 2 :1977Tubular fluorescent lamps for generallighting service:Part 2 Standard lamp data sheets

IS 10322 : Part 1 :1982Luminaires:Part 1 General requirements

IS 11000 : Part 2 : Sec 1 :1984 Fire hazard testing:Part 2 Test methods,Section 1 Glow-wire test and guidance

IS 11000 : Part 2 : Sec 2 :1984 Fire hazard testing:Part 2 Test methods,Section 2 Needleflame test

IS 12063 :1987Classification of degrees of protectionprovided by enclosures of electricalequipment