IS 13340 : Part 2 : 2012/IEC 60831-2 : 1995 Shunt Power Capacitors of the Self-Healing Type for ac Systems having a Rated Voltage up to and including 1 000 V Part 2 Ageing Test, Self-healing Test and Destruction Test

(Superseding IS 13341 : 1992)

ICS 29.120.99;31,060,70 ETD 29

Reaffirmed 2022

NATIONAL FOREWORD

This Indian Standard (Part 2) which is identical with IEC 60831-2 : 1995 ‘Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 2: Ageing test, self-healing test and destruction test’ issued by the International ElectrotechnicalCommission (IEC) was adopted by the Bureau of Indian Standards on the recommendation of the Power Capacitors Sectional Committee and approval of the Electrotechnical Division Council.

This standard was previously published as IS 13341 : 1992 ‘Requirements for ageing test, selfhealing test and destruction test on shunt capacitors of the self-healing type for ac power systems having a rated voltage up to and including 650 V’. The committee has now decided to adopt IEC 60831-2 : 1995 in dual numbering as Part 2 of IS 13340. This standard supersedes IS 13341 : 1992 and after the publication of this standard IS 13341 shall be treated as withdrawn.

This standard is published in two parts and brought under IS 13340 series. Other part in this series is:

Part 1 General performance, testing and rating - Safety requirements - Guide for installation and operation

The text of IEC Standard has been approved as suitable for publication as an Indian Standard without deviations. Certain conventions are, however, not identical to those used in Indian Standards. Attention is particularly drawn to the following:

a) Wherever the words ‘International Standard’ appear, referring to this standard, they should be read as ‘Indian Standard’.

b) Comma (,) has been used as a decimal marker while in Indian Standards, the current practice is to use a point (.) as the decimal marker.