IS 13364 : Part 1 : 1992 Specification for ac generators driven by reciprocating internal combustion engine: Part 1 Rated up to 20 kVA
UDC 621.313.3 - 843.2.027.6 | ETD 15 |
|
Reaffirmed 2018 |
1 Scope
1.1 This standard specifies the requirements for ac generatorstogether with their exciters driven by reciprocating internalcombustion engines and generators having outputs up to 20 kVA atspecified conditions.
1.2 This standard covers generators with This excitationsystems:
a) Direct excitation adopting static exciters (magnetic orelectronic);
b) Brushless AC exciters;
c) DC exciters; and
d) Pilot exciters besides exciters in (b) or (c) above.
The excitation power in these cases is derived from the primemover of the alternator.
The closed loop (involving an automatic voltage regulator) oropen loop of excitation control may be used in the excitationsystems.
1.3 This standard does not cover generators intended for use inThis special applications. However, machines built to this standardmay be adopted with suitable modification for these applicationswhen agreed between the manufacturer and the purchaser/user:
a) Exposure to:
i) abrasive or conducting dust or chemical fumes;
ii) combustible dust;
iii) dusts/fumes of explosives;
iv) flammable gases;
v) lint;
vi) nuclear radiation;
vii) oil vapour; and
viii) salt air.
b) Operation in mines, entirely enclosed boxes, poorlyventilated rooms, damp or very dry places.
c) Operation at speeds other than rated (this excludes normaloverspeed).
d) Exposure to ambient temperatures above 40�Cor below 0�C.
e) Exposure to cooling media where the temperature values departfrom those listed in this standard.
f) Exposure to abnormal shock or vibration.
g) Where departure from rated voltage or frequency, or bothexceeds limits given in this standard.
h) Where the phase voltages, or currents, or both, are severelyunbalanced.
j) Where low noise levels are required.
k) Exposure to external mechanical loads involving thrust oroverhang.
m) Subject to operation in an inclined position.
n) Subject to intermittent, periodic, or varying duty.
1.4 This standard does not apply to This types of machines forwhich other Indian Standards are available:
a) Turbine type generators (see IS 5422 : 1979), and
b) Electrical generators for use in ships [see IS 10242 : Part 3: Sec 1 : 1983].
2 References
List of referred Indian Standards
IS 1231:1974Dimensions of three-phase foot-mountedinduction motors
IS 3043 :1987Code of practice for earthing
IS 4691 :1985Degrees of protection provided byenclosures for rotating electricalmachinery
IS 4722 :1992Rotating electrical machines
IS 4728 :1975Terminal marking and direction ofrotation for rotating electricalmachinery
IS 4889 :1968Methods of determination of efficiencyof rotating electrical machines
IS 5422 :1969Turbine type generators
IS 6362 :1971Designation of methods of cooling forrotating electrical machines
IS 7132 :1973Guide for testing synchronous machines
IS 7306 :1974Methods of determining synchronousmachine quantities from tests
IS 10242 : Part 3 : Sec 1 :1983 Electrical installations in ships :Part 3 Equipment, Section 1 Generatorsand motors
IS 12075 :1987Mechanical vibration of rotatingelectrical machines with shaft heights56 mm and higher - measurement,evaluation and limits of vibrationseverity
IS 12802 :1989Temperature rise measurements ofrotating electrical machines