IS 13648 : 1993 Power electronics capacitors

UDC 621.319.4.016.2 : 621.38 ETD 29
Reaffirmed 2018

1 Scope

1.1 This standard applies to capacitors intended to be used inpower electronic equipment, particularly for: (a) Semiconductorswitching and protection, and (b) filtering (see Note 2).

1.1.1 The rated voltage of these capacitors is limited to 10 000V. The basic frequency of the systems in which these capacitors areused is usually below 1 000 Hz, while the pulse frequencies may goup to several 1 000 Hz and in some cases beyond 10 000 Hz.

1.1.2 This standard distinguishes ac capacitors and dccapacitors and are considered as components housed in closedcabinets.

Notes

1 The requirements for capacitors, protected by internal fusesand internal disconnecting devices, as well as requirements forself-healing tests, endurance tests and destruction tests arecovered separately in IS 13580 : 1992 and IS 13341 : 1992.

2 This standard covers an extremely wide rage of capacitortechnologies for numerous applications. Examples are given inSection 6.

2 References

List of Referred Indian Standard

IS 3716 :1978 Application guide for insulationcoordination

IS 2500 : Part 1 :1973Sampling inspection tables:Part 1 Inspection by attributes and bycount of defects

IS9000Basic environments testing procedures forelectronic and electrical items:

Part 4 :1979Part 4 Damp heat (steady state)

Part 5 : Sec 1 and 2 :1981 Part 5 Damp heat (cyclic)

Part 8 :1981Part 8 Vibration (sinusoidal test) test

IS 13580 :1992Internal fuses and internal overpressuredisconnector for power electroniccapacitors

IS 13341 :1992Requirements for ageing test,self-healing test and destruction test onshunt capacitors of the self-heating typefor ac power systems having a ratedvoltage up to and including 650 V.

IS 13666 :1993Draft energy storage capacitors