IS 14458 : Part 6 : 2020 Retaining Wall For Hill Area - Guidelines - Part 6 Construction of Gabion Walls
New Standard from Last Update.
1 SCOPE
This standard (Part 6) deals with the construction aspects of gabion walls used for protecting cut slopes as well as natural slope at the toe of slope.
2 REFERENCES
The following standards contain provisions, which through reference in this text constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below:
432 (Part 2) : 1982 Specification for mild steel and medium tensile steel bars and hard drawn steel wire for concrete reinforcement: Part 2 Hard-drawn steel wire (third revision)
14458 (Part 5) : 2016 Retaining wall for hill areas - Guidelines: Part 5 Construction of cement stone masonry walls
16013 : 2012 Welded wire gabions (metalliccoated or metallic-coated with PVC coating) - Specification
16014 : 2012 Mechanically woven, doubletwisted, hexagonal wire mesh gabions, revet attresses and rock fall netting (galvanized steel wire or galvanized steel Wire with PVC coating) - Specification