IS 14615 : Part 2 : 2018/ISO 5167-2 : 2003 Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross- Section Conduits Running Full Part 2 Orifice Plates

ICS 17.120.20

WRD 01

Reaffirmed 2023

NATIONAL FOREWORD

This Indian Standard (Part 2) which is identical to ISO 5167-2 : 2003 ‘Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 2: Orifice plates’ issued by the International Organization for Standardization (ISO) was adopted by the Bureau of Indian Standards on the recommendation of the Hydrometry Sectional Committee and approval of the Water Resources Division Council.

This standard is being published in five parts. Other parts in the series are:

Part 1 General terms and definitions

Part 3 Nozzles and Venturi nozzles

Part 4 Venturi tubes

Part 5 Cone meters

The text of ISO Standard has been approved as suitable for publication as an Indian Standard without deviations. Certain conventions are, however, not identical to those used in Indian Standards. Attention is especially drawn to the following:

a) Wherever the words ‘International Standard’ appear referring to this standard, they should be read as ‘Indian Standard’.

b) Comma (,) has been used as a decimal marker, while in Indian Standards, the current practice is to use a point (.) as the decimal marker.