IS 15672 : 2006 Flow Measurement of Natural Gas and Fluids by Coriolis Meters

ICS 75.160.30;75.180.30 PGD 26
Reaffirmed 2022

1 Scope

1.1 This standard provides guidance on seIection,installation, calibration, performance and operation ofCoriolis meters for the determination of mass flow,density, volume flow and other related parameters offluids, synonymous for liquids and gases. For gases itspecifies the determination of gas mass flow andstandard volume flow (using pre-determined standarddensity). It also specifies appropriate considerationsregarding the fluids to be measured.

1.2 The primary purpose of Coriolis meter is tomeasure mass flow. Some of the meters offeradditional possibilities for determining the densityand temperature of fluids. From the abovemeasurements, volume flow and other relatedparameters may be determined. The Coriolis meter isused for fluids mixture of solids, gas in liquids andmixture of liquids.