IS 16614 : Part 1 : 2018 Double-Capped LED Linear Lamps Part 1 Safety Specification
Reaffirmed 2024
1. SCOPE
This standard specifies the safety and interchangeability requirements together with the test methods and conditions required to show compliance of double-capped LED retrofit and conversion lamps with G5 and G13 caps, for use in fittings for LED linear lamps and also intended for replacing fluorescent lamps with the same caps, having:
a) a rated power up to 30 W;
b) a rated voltage of up to 250 V ac; and
c) nominal lengths from 300 mm to 1 500 mm.
The existing luminaires, into which the double-capped LED retrofit lamps are fitted, can be operated with electromagnetic or electronic control gear.
The requirements of this standard relate to type and acceptance testing. Recommendations for whole product testing or batch testing are given in Annex A.
NOTE - Where in this standard the term -lamp(s)- is used, it is understood to stand for “double-capped Linear Tubular LED lamp(s)”.
The requirements in this standard are given for general lighting service (excluding for example explosive atmospheres).
Performance requirements of the lamps covered in this standard will be covered in a separate standard.
For lamps for other applications additional requirements may apply.
2. REFERENCES
The following standards, in whole or in part, are necessary adjuncts to this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced standard (including any amendments) applies.
1534 (Part 1) Ballasts for tubular fluorescent lamps: Part 1 Switch start circuit
2215 : 2006 Starter for fluorescent lamps
2418 Tubular fluorescent lamps for general lighting service:
(Part 1) Safety requirements (second revision) (under preparation)
(Part 2) Performance requirements (second revision) (under preparation
(Part 3) : 1977 Tubular fluorescent lamps for general lighting service: Dimensions of G-5 and G-13 bi-pin caps
(Part 4) : 1977 Tubular fluorescent lamps for general lighting service: Part 3 Go and no-go gauges for G-5 and G-13 bi-pin caps
3323 : 1980 Bi-pin lamp holders for tubular fluorescent lamps
8913 : 1978 Method of measurement of lamp cap temperature rise
10322 (Part 1) : 2014 Luminaire: Part 1 General requirements and tests
11000 (Part 2/Sec 1) : 2008 Fire hazard testing: Part 2 Test methods, Section 1 Glow-wire apparatus and common test procedure
15885 Safety of lamp controlgears:
(Part 1) : 2011 General requirements
(Part 2/Sec 13) : 2012 Particular requirements, Section 13, Electronic controlgear for LED module
16101 : 2012 Terms and definitions of LEDs and LED modules in general lighting
16103 (Part 1) : 2012 LED modules for general lighting: Part 1 Safety requirements
16104 : 2012 Electronic controlgear for LED module - Performance requirements
IEC 60598-1 : 2014 Luminaires - Part 1: General requirements and tests
IEC 61347-1 : Lamp controlgear: Part 1 General and 2015 safety requirements