IS 369 : 2019 Household Electric Direct — Acting Room Heaters — Performance Requirements
Revised Standard from Last Update.
1. Scope
This standard applies to electric direct-acting room heaters. They may be portable, stationary, fixed, or built-in.
Notes — Example of the heaters covered in this standard are:
a) Panel heater
b) Convector heater
c) Fan heater
d) Radiant heater
e) Visibly glowing radiant heater It does not apply to:
a) Thermal-storage room heaters;
b) Heating appliances incorporated in the building structure;
c) Central heating systems;
d) Heaters connected to an air duct; and
e) Wall-paper carpets or drapes incorporating flexible heating elements.
This standard defines the main performance characteristics of direct-acting room heaters and specifies methods for measuring these characteristics, for the information of users.
These performance requirements are additional to the safety requirements given in IS 302-2-30.
2. References The following standards are necessary adjunct to this standard.
IS 302-2-30 (2007) Safety of household and similar elect r ical appl iances : Part 2 Particular requirements for room heaters
IS 2500 (Part 1) : 2000 Sampling procedures for inspection by attributes : Part 1 Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection