IS 371 : 1999 Ceiling Roses - Specification
ICS 29.140.10 ETD14
Reaffirmed 2020
1 Scope
1.1 This standard covers ceiling roses of surface and semi-recessed types for use with simple or multiple pendant lighting fitting and for the use in circuits in which the nominal voltage does not exceed 250V and the current does not exceed 6A and intended to be used in final circuits with rated current 16A maximum for ceiling roses with screw-type supply terminals or 10 A maximum for ceiling roses with screwless supply terminals. The requirements specified in this standard have particular reference to safety in use.
2 References
IS 302 : Part 1 : 1979 Safety of household and similar electrical appliances: Part 1 General requirements
IS 694 : 1990 PVC insulated cables for working voltage up to and including 1100 V
IS 732 : 1989 Code of practice for electrical wiring installations
IS 1401 : 1970 Accessibility test probes
IS 2500 : Part 1 : 1992 Sampling inspection procedure: Part 1 Attribute sampling plans indexed by acceptable quality level (AQL) for lot-by-lot inspection
IS 2667 : 1988 Fittings for rigid steel conduits for electrical wiring
IS 3419 : 1988 Fittings for rigid non-metallic conduits
IS 5133 Boxes for enclosures of electrical accessories:
Part 1 : 1969 Steel and cost iron boxes
Part 2 : 1969 Boxes made of insulating material
IS 9968 : Part 1 : 1988 Elastomers insulated cables: Part 1 For working voltages up to and including 1100 V
IS 11000 : Part 2 : Sec 1 : 1984 Fire hazard testing: Part 2 Tests methods, Section 1 Glow-wire test and guidance