IS 4160 : 2005 Interlocking Switch Socket Outlets - Specification
ICS 29.120.30 | ETD 14 |
|
Reaffirmed 2020 |
1 Scope
Replace this clause of IS 1293 by the following:
This standard applies to switched socket-outletswith interlock for ac only, for fixed electrical installations, with orwithout earthing contact, with rated voltage above 50 V but not exceeding440 V and a rated current not exceeding 32 A, intended forhousehold and similar purposes, either indoors or outdoors.
Switched socket-outlets with interlock accordingto this standard consist of a combination of socketoutletsaccording to IS 1293, interlocked with a switch according to IS 3854supplied as a complete unit,
The rated current is limited to 16A maximum forfixed accessories provided with screwless terminals.
This standard does not cover requirements for flushmounting boxes.
However, it covers those requirements for surfacetypemounting boxes which are necessary for the tests on socket-outlets.
NOTES
1 General requirements for mounting boxes are coveredby IS 14772.
2 Interlocked socket-outlets incorcorporating devicesaccording to IS 8828 and IS 12640 ( Part 1 ) and IS 12640 ( Part 2 )are not covered by this standard. These standards may be used as a guide forthe requirement and tests of these accessories whererelevant.
This standard does not apply to:
a) Interlocked socket-outlets for industrialpurposes; and
b) Interlocked socket-outlets for SELV.
Accessories complying with this standard are suitablefor use at an ambient temperature not normally exceeding35�C, but occasionally reaching 45�C.
2 References
This clause of IS 1293 is applicable, except as follows:
Add to the list of normative references:
IS No. | Title |
IS 302-1 : 1979 | Safety of household and similar electrical appliances : Part 1 General requirements |
IS 1293 : 2005 | Plugs and socket-outlets for rated voltage up to and including 250 volts and rated current up to and including 16 A ( third revision ) |
IS 3854 : 1997 | Switches for household and similar fixed-electrical installation ( second revision ) |
IS 8828 : 1996 | Circuit breakers for over current protection for household and similar installation ( second revision ) |
12640 | Residual current operated circuit- breakersfor household and similar uses: |
IS Part 1 : 2000 | Circuit breakers without integral over current protection ( RCCBs ) |
IS Part 2 : 2001 | Circuit breakers with integral overcurrent protection ( RCBOs ) |
IS 14772 : 2000 | For enclosures for accessories for household and similar fixed installation |