IS 5117 : 2023 Commercial Boiling Burners for Use with LPG - Specification
Revised Standard from Last Update.
1. SCOPE
1.1 This standard specifies requirements and tests for appliances having boiling burners for heating, removable pans, kettles, and stockpots using LPG at 2.942 kN/m2 (30 gf/cm2). The appliances include hot plates on ranges, boiling tables, stockpot stoves, and separate boiling burners. It also includes griddle plates used for dry frying.
1.1.1 The boiling burners may be open, in which the burner is covered by a removable grid, or solid, in which the burner is covered by a solid plate usually with a removable solid ring. Separate test requirements are given for open and solid types, although similar test methods are employed.
2 REFERENCES
The standards listed below contain provisions which, through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards listed below:
IS 5116 : 2020 Domestic and commercial equipment for use with LPG - General requirements (fourth revision)
IS 6480 : 1988 Glossary of terms relating to domestic and commercial gasburning appliances (first revision)