IS 516 : Part 2 : Sec 3 : 2022 Hardened Concrete - Methods of Test Part 2 Properties of Hardened Concrete other than Strength Section 3 Oxygen Permeability Index
New Standard from Last Update.
1. SCOPE
This standard (Part 2/Sec 3) covers the test for the determination of oxygen permeability index of cement concrete having maximum nominal size of the aggregate not more than 20 mm.
2. REFERENCES
The following standards contain provisions, which through reference in this text constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below:
516 (Part 4) : 2018 Hardened concrete - Methods of test: Part 4 Sampling, preparing and testing of concrete cores
1199 (Part 5) : 2018 Fresh concrete - Methods of sampling, testing and analysis: Part 5 Making and curing of test specimens