IS 7290 : 1979 Recommendations for use of polyethylene film for water-proofing of roofs

UDC 678.742.2-416 : 699.82 : 69.024.15 CED 41
Reaffirmed 2020

1 Scope

1.1 This standard provides recommendations for the laying ofpolyethylene film for waterproofing of roofs.

2 References

IS 2 :1960 Rules for rounding offnumerical values

IS 73 :1961 Specification for pavingbitumen

IS 2115 : 1967 Codeof practice for flat-roof finish : mud PHUSKA

IS 2508 : 1977Specification for low density polyethylene film

IS 3067 : 1966 Codeof practice for general design details andpreparatory work for damp-proofing and waterproofing ofbuildings

IS 3384 : 1965Specification for bitumen primer for usc inwaterproofing and damp-proofing