IS 9566 : 1980 Specification for High Tension Connecting Wires for use in Television Receivers

UDC 621.315.336.9 : 678.073 : 621.397.62 LTD 6
Reaffirmed 2020

1 Scope

1.1 This standard covers the requirements of single high tensionpolyethylene insulated, screened or unscreened, PVC sheathedconnecting wires, having a rated working voltage of 20 kV dc and amaximum working temperature of 85°C, primarilymeant for use in television receivers.

2 References

IS 2 : 1960Rules for rounding off numerical values

IS 1885 : Part XXXII :1971 Electrotechnical vocabulary:Part XXXII Cables, conductors andaccessories for electricity supply

IS 5026 :1969General requirements and tests for radiofrequency cables

IS 5831 :1970Specification for PVC insulation and sheathof electric cables

IS 6474 :1971Specification for polyethylene insulation and sheath-of electric cables