IS 9713 : 1983 Hot rolled electrolytic copper wire rod for electrical conductors

UDC 669.337-426-122.4 : 621.315.55 MTD 8
Reaffirmed 2021

1 Scope

1.1 This standard covers the requirements of the hot-rolled electrolyticcopper wire rods used as drawing stock for electrical conductors.

1.2 The wire rods shall be round in section having diameter up to 18 mm.

2 References

IS 2 :1960Rules for rounding off numerical values

IS 191 : Part 5 : 1980 Specification for copper:Part 5 Electrolytic tough pitch copper (ETP)

IS 440 :1964Methods of chemical analysis of copper

IS 1387 :1967General requirements for the supply ofmetallurgical materials

IS 2654 :1977Method for tensile testing of copper and copperalloys

IS 3288 : Part 1 :1981 Glossary of terms for copper and copper alloys:Part 1 Cast form and wrought from (main types)