IS/ISO 11843 : PART 3 : 2003 : Capability of Detection Part 3 Methodology for Determination of the Critical Value for the Response Variable When no Calibration Data are Used
ICS 03.120.30; 17.020 | MSD 3 |
|
Reaffirmed 2023 |
NATIONAL FOREWORD
This Indian Standard (Part 3) which is identical with ISO 11843-3 : 2003 ‘Capability of detection — Part 3: Methodology for determination of the critical value for the response variable when no calibration data are used’ issued by the International Organization for Standarization (ISO) was adopted by the Bureau of Indian Standards on the recommendation of the Statistical Methods for Quality and Reliability Sectional Committee and approval of the Management and Systems Division Council.
An ideal requirement for the capability of detection with respect to a selected state variable would be that the actual state of every observed system can be classified with certainty as either equal to or different from its basic state. However, due to systematic and random distortions, this ideal requirement cannot be satisfied because:
— in reality all reference states, including the basic state, are never known in terms of the state variable. Hence, all states can only be correctly characterized in terms of differences from basic state, that is, in terms of the net state variable.
— the calibrations and the processes of sampling and sample preparation add random variation to the measurement results.